上海力士樂(lè)驅(qū)動(dòng)器維修:上海仰光電子科技有限公司專(zhuān)業(yè)從事各品牌伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修,觸摸屏維修,變頻器維修,伺服器維修,伺服控制器維修,數(shù)控系統(tǒng)維修改造,機(jī)器人維修保養(yǎng)以及各種板卡,芯片級(jí)維修維護(hù),免費(fèi)檢測(cè),快速維修,部分立等可取!F860 Overcurrent: Short in Powerstage過(guò)電流:功率級(jí)短路。
力士樂(lè)dds伺服驅(qū)動(dòng)器維修:
Description:
The current in the power transistor bridge has exceeded twice the peak
current of the drive. As a result, the drive will be immediately turned off.
The drive has switched to a torque-free condition. An optional brake is
immediately activated.
功率晶體管橋中的電流已超過(guò)峰值的兩倍驅(qū)動(dòng)器的電流。因此,驅(qū)動(dòng)器將立即關(guān)閉。
驅(qū)動(dòng)器已切換到無(wú)扭矩狀態(tài)?蛇x制動(dòng)器為立即激活。
Cause:原因:
1. Short circuit in the motor cable.
電機(jī)電纜短路。
2. Defective power section of the drive controller.
驅(qū)動(dòng)控制器的電源部分故障。
3. The current regulator was incorrectly parameterized
電流調(diào)節(jié)器參數(shù)化錯(cuò)誤
Remedy:
1. Check the motor cable for a short.
檢查電機(jī)電纜是否短路。
2. Exchange drive controller.
更換驅(qū)動(dòng)器控制器。
3. The current regulator parameters should not deviate from the
default values of the feedback.
電流調(diào)節(jié)器參數(shù)不應(yīng)偏離反饋的默認(rèn)值。
友情提示:請(qǐng)勿自行拆卸檢查或交給非專(zhuān)業(yè)人士,以免越修越壞,造成不必要的經(jīng)濟(jì)損失!早一天聯(lián)系,少一天損失!上海仰光電子科技有限公司 因?yàn)閷?zhuān)注,所以專(zhuān)業(yè)!
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專(zhuān)業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修